A method for measuring high viscosity in surface tension

更新时间:2017-04-20 10:32:42点击次数:1421次字号:T|T
This method is applied in the measurement of the viscosity of more than 500CP.S liquid, measured for more than 5 minutes, the measured value will reach a stable (not including the liquid itself with the nature of the change) such as glycerol, viscose and
A method for testing high viscosity liquids
This method is applied in the measurement of the viscosity of more than 500CP.S liquid, measured for more than 5 minutes, the measured value will reach a stable (not including the liquid itself with the nature of the change) such as glycerol, viscose and so on.
Method 1, manual mode:
(1) hang the platinum plate and return to zero;
(2) QBZY surface tension meter "manual / automatic" to the manual state. That is, the indicator light does not light;
(3) Follow the steps below to raise the sample stage to the platinum plate:
A Press the "Up" button to raise the sample.
B Press the "Stop" button when the platinum plate comes into contact with the sample surface. Stop the rise of the sample stage. After the stop, the platinum plate should be exposed to the sample surface, and the LCD screen shows the surface tension value is negative. Note that this exposure to the height of the white gold plate into the sample depth of about 1mm or so (in fact because of the high viscosity of the sample, the white gold plate began to contact the sample can not really insert but the sample hold up).
(4) Remove the white gold plate and wet the 5mm height (not too high, and if the display value is more than 5mN / m, please scratch the white surface of the sample until the display value is less than 5mN / m)
(5) to re-hang the platinum plate, this time the sample will come into contact with the platinum plate, and the phenomenon of surface tension, the completion of the wet process.
(6) and so relatively stable when reading readings.

Method 2, automatic operation:
We recommend that customers use this method to operate, but if the time requirements are higher, please test according to the third method.
(1) hang the platinum plate and return to zero;
(2) Remove the platinum plate and wet the 5mm height;
(3) the use of tissue paper will be attached to the white gold plate on the liquid wipe some;
(4) re-hang the platinum board, then the display value will be greater than 0, please do not return to zero, if the display value is greater than 5mN / m, please wipe some;
(5) press the "up" button to test, remember the stability value.
(编辑:HengZheng)
0 条评论
不想登录?直接点击发布即可作为游客留言。

新闻中心列表

公司新闻
行业资讯

新闻推荐

FA系列电子天平日常使用方法是...

FA系列电子天平按结构可分为上皿式和下皿式两种。称盘在支架上面为...

JA系列电子天平怎么用?

小颗粒物和液体在称量时一般都是需要使用容器,我们可先将空的容器放...

电子天平称重结果不稳定有哪些原...

通过拆解,可以看出电子天平是精密的机电仪表,比较娇气,操作规程要...

卤素水分测定仪测量不准确的原因...

卤素水份仪是一种新型快速的水分检测仪器。采用环形卤素灯加热,智能...

如何选购合适的电子天平?

选择电子天平应该从电子天平的绝对精度(分度值e)上去考虑是否符合称量...

电子天平校准的方法有几种?

电子天平在长时间未使用或第一次使用前都要进行校准,否则就会导致测...

FA系列电子天平使用方法

FA系列电子天平采用高精度电磁力平衡传感器。使得测量结果精确性更...

联系我们

地址:江苏省常州市钟楼区龙城大道2188号新闸科技园

联系人:查小姐
邮编:213000
电话:0519-83263587
传真:0519-83268313
网址:http://www.czhzyq.com/

联系我们
地址:常州市钟楼区龙城大道2188号新闸科技园10栋313
联系人:查小姐
电话:0519-83263587
传真:0519-83268313
网址:http://www.czhz17.com
关注衡正
Copyright © 2017 - 2024 All Rights Reserved 常州市衡正电子仪器有限公司 版权所有  苏ICP备17024635号 技术支持:冉冉科技 网站地图