Dial viscometer Notes on installing and unloading the rotor

更新时间:2017-04-20 10:31:02点击次数:1948次字号:T|T
The operator must be careful when installing or unloading the rotor. All viscometers can measure extremely small torques due to the rotation of the rotor within the sample fluid. This requires that the friction inside the instrument be kept at a minimum.
The operator must be careful when installing or unloading the rotor. All viscometers can measure extremely small torques due to the rotation of the rotor within the sample fluid. This requires that the friction inside the instrument be kept at a minimum. The instrument is supported by a pivot system and a gemstone bearing system, with almost no friction, as shown on the right. The support mechanism is in the pivot cup just above the position where the rotor is installed.

When the rotor is installed or unloaded, any downward force or lateral movement will cause great wear to the support system.
When you tighten or loosen the rotor, the correct way to install and unload the rotor is to gently lift the nut at the rotor and then lift it firmly. Also remember that the rotor is fixed from the opposite direction of the thread (left hand).
Similar to the precautions described above can ensure that your viscometer or rheometer can provide reliable service for a long time.
Vibration check, there is a quick check to determine the pivot point of your instrument and the status of the gem support system, you can follow the following steps:
1, do not install the rotor in the case, to ensure that the instrument zero scale in the reading window.
2, observe the red pointer just stopped at the zero indicator line.
3. Lift the nut at the rotor and rotate until the indicator reaches + 20%.
4, put down the nut at the rotor and let go, observe the red pointer until the vibration stops. Record the approximate number of vibrations and the time of vibration.
5, red pointer at this time should still stop at the zero indicator line mark. If not stopped at zero, indicating that the instrument's support system has been a certain damage. Continue to repeat the calibration procedure, if the calibration check falls outside the allowable range, call the local office or call the manufacturer directly to tell you the results and get the service for your instrument.
(编辑:HengZheng)
0 条评论
不想登录?直接点击发布即可作为游客留言。

新闻中心列表

公司新闻
行业资讯

新闻推荐

教您使用FA系列电子天平妙招

JA系列电子天平如何选购?

电子天平如何测量固体密度

该挑选内校还是外校电子天平

经常应用天平的顾客应当了解,强制的计量设备是规定外校的。而又有很...

怎么样调节电子天平水平

电子天平在称量过程中会因为摆放位置不平而产生测量误差,称量精度越...

电子天平未来的广泛运用

电子天平采用人体工程学设计,让日常常规称量轻松。基本功能唾手可得...

台式电子天平机械故障解决方案

台式电子天平品种繁多,使用也比较普遍。以其品种繁多,台式电子天平...

联系我们

地址:江苏省常州市钟楼区龙城大道2188号新闸科技园

联系人:查小姐
邮编:213000
电话:0519-83263587
传真:0519-83268313
网址:http://www.czhzyq.com/

联系我们
地址:常州市钟楼区龙城大道2188号新闸科技园10栋313
联系人:查小姐
电话:0519-83263587
传真:0519-83268313
网址:http://www.czhz17.com
关注衡正
Copyright © 2017 - 2024 All Rights Reserved 常州市衡正电子仪器有限公司 版权所有  苏ICP备17024635号 技术支持:冉冉科技 网站地图